PE-RT II Electrofusion Reducing Tee

PE-RT II Electrofusion Reducing Tee

PE-RT II electrofusion reducing tee is designed to create a 90-degree branch connection where the branch diameter is smaller than the main run. The listed range includes SDR11 / PN16 and SDR17 / PN10 configurations for compatible PE-RT II piping systems.

PE-RT II electrofusion reducing tee

Material: PE-RT II

Jointing: Electrofusion welding

Type: Electrofusion Reducing Tee

Connection: Reducing 90° branch

Pressure Classes: SDR11 / PN16, SDR17 / PN10

Available Configurations: 153

All Models & Specifications

Available PE-RT II electrofusion reducing tee models are grouped by SDR / PN for faster size selection. Dimensions are shown as run × branch × run.

SDR11 / PN16

Size (mm)
25 × 20 × 25
32 × 20 × 32
32 × 25 × 32
40 × 20 × 40
40 × 25 × 40
40 × 32 × 40
50 × 20 × 50
50 × 25 × 50
50 × 32 × 50
50 × 40 × 50
63 × 20 × 63
63 × 25 × 63
63 × 32 × 63
63 × 40 × 63
63 × 50 × 63
75 × 25 × 75
75 × 32 × 75
75 × 40 × 75
75 × 50 × 75
75 × 63 × 75
90 × 25 × 90
90 × 32 × 90
90 × 40 × 90
90 × 50 × 90
90 × 63 × 90
90 × 75 × 90
110 × 32 × 110
110 × 40 × 110
110 × 50 × 110
110 × 63 × 110
110 × 75 × 110
110 × 90 × 110
125 × 32 × 125
125 × 40 × 125
125 × 50 × 125
125 × 63 × 125
125 × 75 × 125
125 × 90 × 125
125 × 110 × 125
140 × 50 × 140
140 × 63 × 140
140 × 75 × 140
140 × 90 × 140
140 × 110 × 140
140 × 125 × 140
160 × 40 × 160
160 × 50 × 160
160 × 63 × 160
160 × 75 × 160
160 × 90 × 160
160 × 110 × 160
160 × 125 × 160
160 × 140 × 160
180 × 63 × 180
180 × 75 × 180
180 × 90 × 180
180 × 110 × 180
180 × 125 × 180
180 × 140 × 180
180 × 160 × 180
200 × 50 × 200
200 × 63 × 200
200 × 75 × 200
200 × 90 × 200
200 × 110 × 200
200 × 125 × 200
200 × 140 × 200
200 × 160 × 200
200 × 180 × 200
225 × 90 × 225
225 × 110 × 225
225 × 125 × 225
225 × 140 × 225
225 × 160 × 225
225 × 180 × 225
225 × 200 × 225
250 × 75 × 250
250 × 90 × 250
250 × 110 × 250
250 × 125 × 250
250 × 160 × 250
250 × 200 × 250
250 × 225 × 250
280 × 110 × 280
280 × 125 × 280
280 × 160 × 280
280 × 200 × 280
280 × 225 × 280
280 × 250 × 280
315 × 90 × 315
315 × 110 × 315
315 × 125 × 315
315 × 160 × 315
315 × 200 × 315
315 × 225 × 315
315 × 250 × 315
355 × 110 × 355
355 × 125 × 355
355 × 160 × 355
355 × 200 × 355
355 × 225 × 355
355 × 250 × 355
355 × 315 × 355
400 × 110 × 400
400 × 125 × 400
400 × 160 × 400
400 × 200 × 400
400 × 225 × 400
400 × 250 × 400
400 × 315 × 400
500 × 110 × 500
500 × 160 × 500
500 × 200 × 500
500 × 250 × 500
500 × 315 × 500
500 × 400 × 500
630 × 110 × 630
630 × 160 × 630
630 × 200 × 630
630 × 250 × 630
630 × 315 × 630
630 × 400 × 630
630 × 450 × 630
630 × 500 × 630

SDR17 / PN10

Size (mm)
355 × 110 × 355
355 × 160 × 355
355 × 200 × 355
355 × 250 × 355
355 × 315 × 355
400 × 110 × 400
400 × 160 × 400
400 × 200 × 400
400 × 250 × 400
400 × 315 × 400
450 × 110 × 450
450 × 160 × 450
450 × 200 × 450
450 × 250 × 450
450 × 315 × 450
450 × 400 × 450
500 × 110 × 500
500 × 160 × 500
500 × 200 × 500
500 × 250 × 500
500 × 315 × 500
500 × 400 × 500
630 × 110 × 630
630 × 160 × 630
630 × 200 × 630
630 × 250 × 630
630 × 315 × 630
630 × 400 × 630
630 × 500 × 630

About PE-RT II Electrofusion Reducing Tee

PE-RT II electrofusion reducing tee is used to create a 90-degree branch where the branch size is smaller than the main run. It is commonly selected when a PE-RT II main pipeline needs to connect to a smaller secondary line while keeping all three connections electrofusion welded.

The first and third dimensions represent the main run size, while the middle dimension represents the reduced branch size. For example, 160 × 110 × 160 mm means a 160 mm main run with a 110 mm branch. The fitting contains integrated electrofusion heating elements at its connection zones and should be selected to match the required pipe sizes and SDR / PN configuration.

About PE-RT II Material

PE-RT II (Polyethylene of Raised Temperature Resistance Type II) is a thermoplastic polyethylene material developed for piping systems that must maintain mechanical strength at elevated temperatures. Compared with conventional polyethylene, PE-RT II offers improved long-term temperature resistance while retaining the benefits of a weldable plastic piping system.

Because PE-RT II remains thermoplastic, compatible pipes and fittings can be joined by butt fusion or electrofusion to create a continuous all-plastic welded pipeline system. The material is also valued for corrosion resistance, resistance to internal scaling, relatively low weight, smooth internal surfaces and installation flexibility.

Operating Temperature

PE-RT II is used in hot- and cold-water and heating applications where elevated-temperature performance is required. The exact allowable temperature depends on pipe and fitting design, SDR or wall thickness, operating pressure and application class. Many PE-RT II piping systems are designed for long-term service in approximately the 70–80°C range, while short-term or maximum design conditions can reach about 95°C. Final temperature and pressure limits should always be confirmed against the actual pipe specification and project design conditions.

Typical Applications

  • Secondary district-heating and heat-distribution networks
  • Building heating and hot-water circulation systems
  • Radiant heating and underfloor heating systems
  • HVAC hydronic heating and cooling circuits
  • Heat-pump and geothermal circulation systems
  • Compatible industrial hot-water and thermal-fluid pipelines

Selection Considerations

For project selection, confirm pipe outside diameter, branch diameter, SDR or wall thickness, design pressure, normal operating temperature, maximum temperature, fluid medium and installation method together. This is especially important for heating networks because allowable pressure changes with operating temperature and intended service life.

Product Details

Overview

The PE-RT II electrofusion reducing tee combines branching and size reduction in one fitting. It allows a smaller branch line to be taken from a larger main while keeping the main run the same diameter on both sides.

Product Features

  • PE-RT II construction
  • Electrofusion jointing
  • Reduced 90-degree branch
  • Main run remains the same diameter
  • Wide range of branch combinations
  • SDR11 / PN16 and SDR17 / PN10 options as listed

Applications & Installation

Typical Applications

Used where compatible PE-RT II heating distribution, hot-water circulation, HVAC hydronic, heat-pump, geothermal or other thermal-fluid mains need to feed a smaller branch line.

Electrofusion Jointing

Prepare and clean all three pipe ends, scrape the fusion areas as required, align and clamp the components, then carry out electrofusion using compatible welding equipment and the applicable project installation procedure. Allow the joint to cool before removing clamps or applying load.

Ordering Information

  • Main run × branch × main run size
  • Required SDR / PN
  • Quantity for each configuration
  • Project operating conditions if required
  • Delivery destination

Frequently Asked Questions

How is the reducing tee size specified?

The dimensions are shown as main run × branch × main run. For example, 200 × 110 × 200 mm has a 200 mm run and a 110 mm branch.

Which pressure classes are listed?

The supplied model list includes SDR11 / PN16 and SDR17 / PN10 configurations. Availability varies by size.

What information is needed for quotation?

Please send the required size combination, SDR / PN class, quantity and delivery destination so we can confirm availability, pricing and lead time.

International Buyer & Sourcing Information

PE-RT II electrofusion reducing tees are suitable for branch connections between different PE-RT II pipe sizes. They are relevant to heating-system distributors, plumbing wholesalers and plastic-pipe importers. For bulk sourcing, provide the main size, branch size, quantity and destination market.

Need PE-RT II electrofusion reducing tees?

Send us your required main and branch sizes, SDR / PN class and quantities for quotation and lead-time confirmation.

Related Products

PE-RT II Electrofusion Equal Tee

PE-RT II Electrofusion Equal Tee

Equal electrofusion tee for 90-degree branch connections in PE-RT II systems.

PE-RT II Electrofusion Reducing Coupler

PE-RT II Electrofusion Reducing Coupler

Electrofusion reducer for straight transitions between different PE-RT II pipe sizes.

PE-RT II Electrofusion Stub End

PE-RT II Electrofusion Stub End

Electrofusion stub end for detachable flanged PE-RT II connections.

Scroll to Top